Two stage vertical flow wetland with recirculation. The system treats the wastewater from the ecological office building. The treated wastewater is reused for toilet flushing.
Two vertical flow wetlands. One is a circulation system treating the pond water. The other treats the wastewater from the outside toilets
- Adapted „French system“ for a nursing home, Hogar de Ancianos Sta. Ana y San Joaquín y Asociación Ayuda Me Perú
- All treated wastewater is reused for irrigation of agricultural used area
- The 2 staged wetland system treats the domestic effluent of 55 residents and employees
- The pre-treatment is carried out on the surface of an planted, vertical flowed gravel bed wetland with 2 charging points, used alternately (2 and 2 days)
- The post-treatment is carried out in an planted vertical flowed sand bed wetland with 4 divisions to maintain always the biologically activity in all parts of the wetland
Design, Construction and Operation and mantainmance by Rotaria del Perú, online monitoring by SCADAweb
Wastewater treatment plant for 1250 p.e., in a very touristic site in the south of France, separative sewerage system, constructed in 1998.
“French sytem” treating raw unsettled sewage in a 2 stage vertical flow reed bed filter without electricity
Recirculated vertical flow French system for 800 p.e. with polishing in a "natural" horizontal flow wetland
A horizontal subsurface flow constructed wetland treating the wastewater from a housing scheme in the tropical island of Mayotte
A vertical flow reed bed (French system) and a vegetated polishing zone (surface flow wetland) treating 117m3/d of domestic effluent from a village with variable population
More...
Allenwiller : a 1700 m², vertical flow reed bed (French system) plus a 960 m² second stage unsaturated vertical flow reed bed filter, treating 495 m3/d of domestic effluent from three villages (1100 PE) in Alsace.
Orelle (French Alps): a 1200 m², vertical flow reed bed (French system) plus a 800 m² second stage unsaturated vertical flow reed bed for domestic effluent under cold climate conditions.
Hollange : a 432 m², vertical flow reed bed (French system) plus a 288 m² second stage unsaturated vertical flow filter, and a 1200 m² vegetated polishing zone treating 102 m3/d of domestic effluent.
Saint Germain sur Ille : a 500 PE waste stabilization pond boosted to 900 PE by addition of reed bed filters with high standards for phosphorus and total nitrogen removal.