Vertical flow reed bed filter (French system) followed by a trickling filter and a treatment with apatite treat the pollution of raw domestic sewage. Capacity : 1500 p.e. Vegetated effluent discharge area before final reject into the small river "Merderic".
Compact reed bed filter to treat raw unsettled domestic sewage (French system). Capacity : 315 people equivalent. Design and build : Epur Nature -2014.
At Escurolles, in central France (Allier), a reed bed fed with raw sewage assures primary and secondary treatment for 705 PE , followed by a tricking filter for polishing and nitrification
One stage of reed beds fed with raw sewage assures primary and secondary treatment for 1200 People Equivalent, followed by a trickling filter for polishing and nitrification. A tertiary UV treatment enables a pathogens removal by 4 U log.
Balhall: A two stage, 185 m2,Aerated saturated vertical flow reed bed system treating 5 m3/d of settled, secondary sewage.
More...
The municipal centralised treatment plant (a classic activated sludge technology) for the wastewater produced by the municipality of Jesi (Ancona province – central Italy) has been upgraded in the year 2002, with the realisation of a new “nitrification-denitrification” compartment and a hybrid Constructed Wetland as polishing stage.