2-stage Vertical Flow Constructed Wetland for the treatment of raw domestic sewage (French system) for 1360 people-equivalent adapted to the local resources and climate with UV tertiary treatment.
Recirculated vertical flow French system for 800 p.e. with polishing in a "natural" horizontal flow wetland
Wastewater treatment plant for 1250 p.e., in a very touristic site in the south of France, separative sewerage system, constructed in 1998.
“French sytem” treating raw unsettled sewage in a 2 stage vertical flow reed bed filter without electricity
Albondon (600 PE) : the first "French system" in Spain, designed and build in 2005 by AKUT and SINT treats the waste water of a town in the foothills of the Sierra Nevada
A vertical flow reed bed (French system) and a vegetated polishing zone (surface flow wetland) treating 117m3/d of domestic effluent from a village with variable population
- Adapted „French system“ for a nursing home, Hogar de Ancianos Sta. Ana y San Joaquín y Asociación Ayuda Me Perú
- All treated wastewater is reused for irrigation of agricultural used area
- The 2 staged wetland system treats the domestic effluent of 55 residents and employees
- The pre-treatment is carried out on the surface of an planted, vertical flowed gravel bed wetland with 2 charging points, used alternately (2 and 2 days)
- The post-treatment is carried out in an planted vertical flowed sand bed wetland with 4 divisions to maintain always the biologically activity in all parts of the wetland
Design, Construction and Operation and mantainmance by Rotaria del Perú, online monitoring by SCADAweb
The Orhei Constructed Wetland treatment plant, the biggest secondary treatment entirely based on CWs in the world
More...
The two stage reed bed system at Aumont (500 PE), in the French Jura mountains meets stringent discharge standards in phosphorous removal through a third stage filtration with reactive media
Llanfair PG: A 440 m2, vertical flow reed bed treating 55m3/d of domestic effluent from a residential education centre.
Wastewater treatment plant for 1200 p.e. at St-Affrique-les-Montagne, south west of France (Tarn), with 1 vertical flow reed bed combined with a surface flow polishing treatment
Balhall: A two stage, 185 m2,Aerated saturated vertical flow reed bed system treating 5 m3/d of settled, secondary sewage.